AI in medical devices · Medium · 13 min lesson
AI development lifecycle: requirements, model design and IEC 62304 alignment
IEC 62304:2006+A1:2015 clauses 4.3, 5 and 8, MDR Annex I section 17.2, EU AI Act Articles 9 and 11, GMLP principles 4 and 6
What you will learn
- Map the stages of an AI development lifecycle onto IEC 62304 processes and say where the standard needs adapting for learned components.
- Write measurable model requirements and justify a software safety class from harm and real risk controls.
- Keep design, third party, training, testing and release records that trace a requirement to a rebuildable released model.
Key takeaways
- IEC 62304 gives the lifecycle process backbone; it does not mention machine learning, so each activity is adapted and the mapping is documented.
- The software safety class follows possible harm and real risk controls, and the justification is reviewed when the model changes (clause 4.3).
- A model requirement states metric, population, threshold, operating point and subgroup floors, and can fail a test (clause 5.2).
- Pretrained models and frameworks are SOUP items: identify them, state requirements and assess limitations (clauses 5.3.3, 8.1.2).
- Keep independent test data, full run logs and a release baseline that lets you rebuild the exact model (clauses 5.7, 5.8).
Free practice question
Halden's plan for the Rhythma arrhythmia model says: 'IEC 62304 does not mention machine learning, so it does not apply to us; we follow our data science practices.' The product is a Class IIa device in the EU.
What is the best assessment of this statement?
Correct, because a standard that does not name machine learning cannot be applied.
Not quite. The standard is a process framework, and MDR Annex I section 17.2 expects a lifecycle, risk management and verification regardless of technique.
Incorrect: the standard is process based, so the activities are applied and adapted to learned components, with the mapping documented.
Correct. IEC 62304 clauses 5 to 9 describe processes that fit learned software, and MDR Annex I section 17.2 expects a documented lifecycle.
Correct, but only for neural networks and not for simpler models.
Not quite. The process framework does not distinguish model types; clause 5 applies to software whatever its internal technique.
Incorrect, because the standard requires a specific neural network architecture.
Not quite. IEC 62304 prescribes processes and records and never prescribes an architecture or algorithm for a software item.
Key terms
- IEC 62304: International standard for medical device software lifecycle processes; amended in 2015 and used as a harmonised route to MDR software requirements.
- software safety class: Class A, B or C assigned from the harm a software failure could contribute to, which sets the rigour of the process (clause 4.3).
- SOUP: Software of unknown provenance: an item not developed under the standard, such as a library or pretrained network.
- operating point: The fixed decision threshold at which sensitivity and specificity are claimed; it is set in the requirement, not tuned afterwards.
- locked test set: Data kept independent of training and tuning, used once per release candidate against predefined acceptance criteria.
- release baseline: The identified set of code, data versions, model file, configuration and documents that define a release.
- GMLP: Ten guiding principles for good machine learning practice in medical devices, published jointly by regulators; guidance, not law.
- traceability: A recorded link from a need through requirement, design, test and release evidence.
Official sources
- IEC 62304:2006/AMD1:2015 Medical device software - Software life cycle processes (ISO catalogue entry)
- Regulation (EU) 2024/1689 (Artificial Intelligence Act), Official Journal
- MDCG 2025-6 / AIB 2025-1: Interplay between the MDR/IVDR and the Artificial Intelligence Act (FAQ)
- Good Machine Learning Practice for Medical Device Development: Guiding Principles (Health Canada, with FDA and MHRA)
Go further
The full lesson has narrated slides, more scenario questions with explained answers and a simulation.