Free lesson previews
Objectives, key takeaways and a free practice question for each lesson.
AI in medical devices
- AI and machine learning landscape in healthcare: device types, claims and stakeholders
- Regulatory landscape for AI medical devices across the EU, US, UK and Israel
- Cybersecurity for AI devices: threat modelling, adversarial attacks and secure design
- Premarket cybersecurity documentation, SBOM and postmarket vulnerability handling
- Post-market monitoring of AI: performance drift, data collection and triggers
- Vigilance, update release and communication for learning and static models
- Technical documentation for AI devices: what the notified body and FDA expect
- Building the AI technical file: model card, data sheet and traceability matrix
- Using AI tools safely in QA/RA work: validation of tools, confidentiality and records
- Practical AI use cases in document control, audits and regulatory intelligence with review controls
- EU AI Act structure: risk tiers, high-risk systems and the Digital Omnibus timelines
- AI Act obligations for providers of medical device AI and the interaction with MDR notified bodies
- FDA approach to AI-enabled devices: submission content, PCCP and transparency
- FDA lifecycle guidance for AI software: performance monitoring and change control
- Integrating AI governance into the QMS: ISO 13485 and ISO/IEC 42001 mapping
- AI policy, roles, objectives and AI-specific procedures and records
- AI risk management with ISO 14971 and ISO/IEC 23894: hazards unique to AI
- Bias, drift, misuse and human factors risk controls with worked examples
- Data governance: sourcing, representativeness, labelling and data quality for AI devices
- Data splitting, leakage, privacy and data management records for audit
- AI development lifecycle: requirements, model design and IEC 62304 alignment
- Configuration management, MLOps controls and change management for models
- Verification and validation of AI: performance metrics, test sets and acceptance criteria
- Clinical validation, subgroup performance, robustness and reporting of results
- Human oversight and transparency: instructions for use, user interfaces and training
- Explainability, automation bias and monitoring of human-AI interaction
- Capstone part 1: review of a fictional AI device file
- Capstone part 2: findings, risk-based conclusions and an improvement plan
ISO 13485
- Capstone part 1: audit case file review of a fictional manufacturer, findings and evidence
- Capstone part 2: writing nonconformities, grading and the closing meeting
- Opening meeting, evidence collection and sampling - ISO 19011 clauses 6.4.3 and 6.4.7 and ISO 13485 clause 8.2.4
- Interviewing, observation and remote audits - ISO 19011 clauses 6.2.3 and 6.4.7 and ISO 13485 clause 8.2.4
- Closing meeting, audit report and conclusions - ISO 19011 clauses 6.4.8 to 6.5 and ISO 13485 clause 8.2.4
- Follow-up: verifying corrective actions and CAPA effectiveness
- Auditor competence, ethics and continual development
- Auditing clause 4: QMS, documents, records and QMS software
- Auditing clause 5: management commitment, planning and review
- Auditing clause 6: competence, infrastructure and work environment
- Auditing clauses 7.1 to 7.3: planning, customer requirements and design control
- Auditing clauses 7.5 and 7.6: production, validation, traceability and calibration
- Auditing clause 8: feedback, complaints, reporting, nonconforming product and CAPA
- MDR conformity assessment for auditors: Annex IX, Annex XI and notified body certificates
- Auditing the MDR QMS (Article 10(9)) and the GSPR (Annex I)
- Auditing technical documentation (Annex II and III) and clinical evaluation
- Auditing PMS, PMCF, PSUR and vigilance (MDR Articles 83 to 92)
- Auditing UDI, EUDAMED, labelling and economic operators (MDR Articles 13 to 16 and 27 to 33)
- Notified body audit conduct: unannounced audits, sampling and nonconformity handling
- FDA QMSR (21 CFR 820) for auditors: structure, differences from ISO 13485 and inspection process
- Mock FDA inspection and inspection-readiness audit
- MDSAP for auditors: audit model, chapters, grading and the five-day rule
- Auditing the ISO 14971 risk management file
- Auditing sterilisation, bioburden and packaging validation
- Auditing clean rooms and environmental monitoring
- Auditing medical device software and QMS software (IEC 62304, cybersecurity, Part 11)
- AI in medical devices I: EU AI Act high-risk obligations and the Digital Omnibus timeline
- AI in medical devices II: FDA PCCP, GMLP, data governance, validation and human oversight
- Capstone: integrated internal audit of a fictional company file
- What a device history record is and what it must show - clauses 7.5.1, 7.5.8 and 7.5.9
- Compiling the batch record - line clearance, in-process checks, deviations, nonconforming product, release and electronic records
- DHR audit practice - reviewing a batch record, reconciliation, planted errors, the traceability test and DHR versus DMR
- What a DMR is today - 21 CFR part 820 (QMSR), ISO 13485 clause 4.2.3 and the contents of the device file
- Building and controlling the device file - structure, index, change control, approvals and links to the design file and technical documentation
- Auditing the device file - sampling, traces, common findings, and DMR versus DHR, DHF and technical file
- Why quality systems exist: medical device history, regulators and the lifecycle
- Quality vocabulary and the regulatory map: ISO 13485, MDR, QMSR and MDSAP in one view
- Clause 4 - QMS requirements, process maps, quality manual and document control
- Clause 4.2.5 - control of records and good documentation practice
- Clauses 5-6 - management responsibility and resource management
- Clause 7.1 - planning of product realization and risk management
- Clause 7.3 - design and development: phases, deliverables and traceability
- Clauses 7.2 and 7.4 - customer requirements and purchasing
- Clause 7.5 - production and service provision, identification and traceability
- Clauses 7.5.6 and 7.6 - process validation and measuring equipment (overview)
- Clause 8 - measurement, analysis and improvement (feedback, audits, nonconformity, CAPA)
- Design and development planning, inputs and outputs - clauses 7.3.2 to 7.3.4
- Design review, verification, validation, transfer and change - clauses 7.3.5 to 7.3.10 and the DHF
- Risk management process: hazards, hazardous situations and risk estimation under ISO 14971
- Risk control, residual risk, the risk management file and production and post-production feedback
- When and why to validate - clauses 7.5.6 and 4.1.6, the GHTF decision tree and the validation master plan
- IQ and OQ in depth - installation checks, worst case challenge, process window and protocol structure
- Performance qualification in depth: sample size, acceptance criteria and the validated state
- Validating a pouch sealer end to end, and auditing clause 7.5.6
- Sterilization methods overview: EtO, gamma, steam and the ISO 11135, 11137 and 17665 families
- Bioburden, sterility assurance level, endotoxin and LAL testing in routine control
- Packaging design and material selection under ISO 11607-1 and sterile barrier systems
- Packaging validation under ISO 11607-2: sealing, ageing, transport and integrity testing
- Complaint handling and corrective action - clauses 8.2.2, 8.3 and 8.5.2
- Preventive action, advisory notices and recalls - clauses 8.3.3, 8.5.3 and vigilance links
- Supplier selection and evaluation - clause 7.4.1 and the approved supplier list
- Purchasing information, verification of purchased product and supplier quality agreements
- Internal audit programme and management review inputs and outputs - clauses 8.2.4 and 5.6
- Management review in practice: data, decisions, actions and records
- IEC 62304 software lifecycle, safety classes and development planning
- Software verification, maintenance, problem resolution and cybersecurity links
FDA
- Choosing the pathway - premarket notification, substantial equivalence, predicates and the alternatives
- Building the submission - 21 CFR 807 subpart E content, performance testing, comparison table, labeling and the 510(k) summary
- The review process - acceptance review, substantive review, AI requests, MDUFA timelines and why 510(k)s stall
- What eSTAR is - the template, who must use it, and how it reaches FDA
- Completing the eSTAR - section by section, attachments and the form checks
- Submitting and managing an eSTAR - Portal upload, holds, requests and the planted-error case
Integrated management systems
- ISO 14001 context, aspects and compliance obligations
- ISO 14001 leadership, objectives, support and operational control
- ISO 14001 performance evaluation, improvement and integration
- ISMS foundations - context, scope, leadership and the CIA triad
- Planning and support - risk, Statement of Applicability, Annex A and documented information
- Operation, evaluation and improvement - audits, certification and the medical-device link
- ISO 9001 basics 1 - Context, scope and the process approach
- ISO 9001 basics 2 - Leadership, planning and support
- ISO 9001 basics 3 - Operation, evaluation and improvement
ISO 42001
- AIMS foundations - what ISO/IEC 42001 is, context, leadership and the AI policy
- Planning and support - AI risk, AI system impact, objectives, competence and documented information
- Operation, performance, improvement and Annexes - running, auditing and certifying an AIMS
EU MDR
- IVDR scope, classification and the structure of the technical file - Regulation (EU) 2017/746, Annex VIII, Annexes II and III
- IVD-specific content - performance evaluation, stability, traceability, GSPR, common specifications and transitional dates
- Notified body assessment of the IVDR file, PMPF, the summary of safety and performance and typical deficiencies
- General safety and performance requirements (Annex I) and the conformity assessment routes
- Clinical evaluation, UDI, EUDAMED and the person responsible for regulatory compliance (Article 15)
- Post-market surveillance system, PMS plan, PSUR and trend reporting
- PMCF, serious incident reporting, field safety corrective actions and timelines
- QMSR and FDA inspection readiness: what changed on 2 February 2026 and how inspections run
- Establishment registration, device listing, MDR reporting and corrections and removals
- Technical documentation per MDR Annexes II and III: structure, GSPR checklist and common deficiencies
- Notified body technical file assessment, sampling and responding to deficiencies
- Capstone part 1: review of a fictional technical file and evidence map
- Capstone part 2: reviewer report, nonconformities and certification decision
- Structure of the MDR technical file - Annex II, Annex III and how notified bodies expect it laid out
- Building each section - GSPR checklist, risk file link, V&V summaries, labelling and the PMS plan
- Notified body review of the technical file - sampling, typical deficiencies, change control and keeping it current
- MDR and IVDR orientation: economic operators, scope and the path to CE marking
- Classification under MDR Annex VIII and IVDR Annex VIII rules with fictional examples
MDSAP
- Auditing organizations and governance - Regulatory Authority Council, recognition, certificates and impartiality
- MDSAP and ISO 13485:2016 - the clause crosswalk and where MDSAP adds more
- Preparing for your first MDSAP audit - readiness, country matrix, document pack and mock questions
- Basic case study - Brannock Spinal Systems first-cycle audit
- Chapter 1 Management - eleven tasks: policy, representative, resources, outsourcing, risk planning and management review
- Chapter 2 Device marketing authorization and facility registration - evidence, changes and notification
- Chapter 3 Measurement, analysis and improvement - sixteen tasks: data, CAPA, complaints, internal audit, nonconforming product
- Chapter 4 Adverse events and advisory notices - reportability, timeframes by country and recalls
- Chapter 5 Design and development - seventeen tasks: planning, inputs, V&V, software, clinical evaluation, change and transfer
- Chapter 6 Production and service controls - twenty-nine tasks, process validation and sterile devices (Annex)
- Chapter 7 Purchasing - twelve tasks: supplier evaluation, purchasing data, critical suppliers and verification
- United States - 21 CFR 820 (QMSR), 803, 806, 807 and 830, and how FDA uses MDSAP reports
- Canada - Medical Devices Regulations SOR/98-282, licences, mandatory problem reporting and recalls
- Brazil - ANVISA RDC 665/2022, RDC 687/2022 B-GMP certification and registration holder duties
- Japan - MHLW Ministerial Ordinance 169 as amended, PMDA, the marketing authorization holder and QMS inspections
- Australia - TGA, TG(MD)R Schedule 3, sponsor-manufacturer agreements and conformity assessment evidence
- Writing nonconformities in MDSAP style - requirement, evidence, finding, the 5W2H and the so-what
- Responding to findings - remediation plans, root cause, effectiveness, 15 and 30 day rules and appeals
- The audit report package - AU F0019.1 report, F0019.2 grading form, guidelines G0019.3 and G0019.4, policy P0019 and P0027
- Regulatory authority exchange - how FDA, Health Canada, ANVISA, PMDA and TGA use reports, special audits and escalations
- MDSAP and EU MDR/IVDR - what MDSAP does not cover, MDCG 2020-14 and integrated audit strategy
- Change and transition - QMSR 2026, Audit Approach revisions, RDC 665, MO 169 and keeping a multi-regulation QMS current
- Audit task workshop - chapter by chapter document audits with planted nonconformities and grading drills
- Capstone A - mock MDSAP audit: planning, opening meeting, Management and Measurement chapters
- Capstone B - mock MDSAP audit: Design, Production, Purchasing, grading, closing meeting and report package
Trading
- Trading practitioner: building a rules-based plan, risk per trade and position sizing
- Trading practitioner: journalling, review metrics and a demo practical
- Trading expert: strategy testing, drawdown control and psychology of discipline
- Trading expert capstone: a complete demo-account strategy review
Educational only, not legal or financial advice. Trading involves risk of loss.